GRUPO ABERDEEN
Grupo Aberdeen · Home
← Grupo Aberdeen

LAMA · ENVIRONMENTAL ANALYSIS AND MEASUREMENT LABORATORY

Data for decisions.
Insight for action.

We establish what to measure, how to collect samples and how to assess the results against RTS 13.05.01:24 and applicable ASA and MARN requirements. Our approach brings together a monitoring program, analytical evidence and practical recommendations for your operations.

Request a monitoring program Explore parameters ↓

MEASUREMENT GUIDED BY REQUIREMENTS

What does
your company need to demonstrate?

The scope depends on the type of wastewater, business activity, flow rate, treatment process, discharge point and permit conditions. Discharge to a river, connection to a sewer and water reuse each require a different assessment.

01 / ASA

Discharge permit.

Supporting evidence for the discharge permit application and its requirements, where applicable. We review where the wastewater is discharged and the nature of the activity that generates it.

02 / RTS AND MARN

Parameters and reports.

Identify the parameters, limits and monitoring frequencies that apply to wastewater and sludge, and maintain the supporting records.

03 / TREATMENT SYSTEM OPERATIONS

Trends and actions.

Assess changes and potential deviations in results to guide operational adjustments and evaluate treatment performance.

RTS 13.05.01:24

All applicable
parameters.

Your monitoring program is tailored to your business activity and the parameters that apply to it. The same set of tests is not appropriate for every company.

Organic loadSolidsChemical conditionsFlow rateProcess-related compounds
Domestic wastewater: discharge to a receiving environment +

Table 2 of the RTS lists nine parameters for domestic wastewater, classified as “ordinary” under the regulation:

  • Chemical oxygen demand (COD)
  • Five-day biochemical oxygen demand (BOD₅)
  • Total suspended solids (TSS)
  • Settleable solids (SS)
  • Oil and grease
  • pH
  • Fecal coliforms
  • Flow rate (Q)
  • Methylene blue active substances (MBAS)

For fecal coliforms, flow rate and MBAS, this table specifies a reporting requirement rather than a numerical limit. These results must be documented and assessed alongside the other regulatory instruments and conditions that apply to the project.

Non-domestic wastewater: basic and sector-specific parameters +

For non-domestic wastewater, the “special” category under the RTS, we review both basic and sector-specific parameters. This includes industrial, agro-industrial, hospital and other activities in that category.

Basic parameters include COD, BOD₅, TSS, oil and grease, pH and temperature. The program also covers any required records and reporting for flow rate and settleable solids. Table 4 and Annex B guide the selection of sector-specific parameters.

The parameters selected depend on the activity and its permit conditions.

The 45 specific parameters listed in the RTS +

Table 4 lists these parameters. The matrix in Annex B and the permit conditions determine which ones apply. This list is not a mandatory testing package for every company, and it does not mean that LAMA performs every test in-house.

Metals and metalloids

Antimony, aluminum, arsenic, barium, beryllium, boron, cadmium, cobalt, copper, hexavalent chromium, iron, lithium, manganese, mercury, nickel, silver, lead, selenium, vanadium and zinc.

Nutrients and other inorganic compounds

Total cyanide, chloride, phosphates, total phosphorus, fluorides, nitrates, nitrites, ammonia nitrogen, total nitrogen, sulfites, sulfates and sulfides.

Other parameters

True color, synthetic phenolic compounds, total herbicides, total petroleum hydrocarbons (TPH), organochlorines, organophosphates and carbamates, methylene blue active substances (MBAS) and turbidity.

Radionuclides, depending on the activity

Gallium-67, iodine-131, phosphorus-32, technetium-99m and thallium-201.

View Table 4 in the official publication
Sludge, water reuse and other sample types +

Sludge requires separate characterization based on its source and intended destination. Reuse of treated water is assessed under the guidelines specific to that use.

Testing well water or drinking water serves a different purpose and falls under a different regulatory framework from testing wastewater discharges. These programs are defined separately. Current sewer operator requirements are also reviewed in their own right.

LAMA · MONITORING IN PRACTICE

From field data
to a technical report.

Monitoring provides evidence of how your system is operating.

Field measurements, such as pH and flow rate, are combined with sampling, chain-of-custody records and the laboratory analyses specified for each discharge. Together, they place the results in the context of the treatment process and the criteria being assessed.

Laboratory analysis provides evidence. Technical interpretation compares each result with the applicable criterion, identifies deviations and guides follow-up. A single measurement cannot demonstrate a company’s overall compliance.

Contact LAMA
Measuring the pH of a liquid sample with a portable instrument
Operational monitoring combines field measurements, sampling and laboratory analysis.

FROM SAMPLING TO INFORMED DECISIONS

One program.
Traceable evidence.

  1. 01

    Define the scope.

    Review the business activity, permits, flow rates and sampling points. Establish the parameters, assessment criteria, sampling frequency and laboratory responsible for the work.

  2. 02

    Plan sampling.

    Plan for representative operating conditions, choose grab or composite sampling as appropriate, and specify field measurements and sample preservation requirements.

  3. 03

    Maintain traceability.

    Arrange sample identification, chain of custody, preservation, transport and documentation.

  4. 04

    Interpret results.

    Compare each result with the applicable criterion, then review trends, operating conditions and potential deviations.

  5. 05

    Plan follow-up.

    Compile the results, observations and recommended actions into a technical file, with a schedule for ongoing monitoring.

Verify the testing scope.

Each proposal identifies the tests, methods and laboratory responsible. For regulatory use, we verify the required accreditation and whether its scope covers the proposed work, including any external services. The RTS requires sampling by an external accredited laboratory.

WHAT YOU RECEIVE

Results you
can use.

  • A sampling program tailored to your operations.
  • Field and chain-of-custody records.
  • Reports from the laboratory responsible for the testing.
  • Comparison with applicable criteria.
  • Recommendations and a follow-up schedule.

We distinguish parameters that must only be reported from those subject to a limit. Where the evidence is insufficient to draw a conclusion, we explain what still needs to be verified.

DOCUMENTATION AND FOLLOW-UP

MARN, SEA and ASA.

Annual sampling schedules for wastewater treatment facilities are submitted through SEA. We compile flow rates, discharge points, parameters, sampling dates, laboratory details and supporting documents for submission and follow-up.

The ASA discharge permit, the environmental permit and MARN reporting are separate obligations. We identify which apply and keep their requirements and supporting evidence distinct.

View the current procedure

A test result describes the sample and the conditions assessed. It does not certify the company as a whole or, on its own, guarantee ongoing compliance.

Official sources and how they apply +

Reference reviewed in November 2026: the final RTS 13.05.01:24 published in the Diario Oficial, rather than the consultation draft. Permit conditions, the receiving environment and the activity are reviewed for each project.

THE NEXT STEP

Let’s talk about
your project.

Tell us your business activity, location and what you need to resolve. For an existing system, include the model and the issue you have noticed. For a new system, share its intended use and any known flow rate or capacity.

Contact Grupo Aberdeen
WhatsApp