GRUPO ABERDEEN
Grupo Aberdeen · Home
← Back to technologies

SAMPLING · FLOW · DATA

Teledyne ISCO

Better measurements.
Confident decisions.

Teledyne ISCO BLZZRD sampler installed at a monitoring site
BLZZRD · monitoring in Chojnice, Poland. Manufacturer source
This is not a Grupo Aberdeen project.

MEASURE · RECORD · SAMPLE

From sensor
to sample.

Choose the flow meter, sensors and sampler as a system, matched to the conditions at your monitoring site.

01 / CONFIGURABLE PLATFORM

Signature.
The right technology for your discharge monitoring.

A configurable flow monitoring platform for open channels and discharge points. It supports level and area-velocity measurement, logs multiple parameters and keeps an event history to help assess data integrity.

Choose ultrasonic or bubbler level measurement, submerged area-velocity sensing, LaserFlow or LevelRay radar. Add pH and temperature monitoring as your application requires.

Sensors and modules are specified separately to suit the channel, water quality, installation conditions and safety requirements.

Ask about Signature
Teledyne ISCO Signature flow meter
Product image from the manufacturer. Sensors and interfaces vary with the configuration.

MEASUREMENT TECHNOLOGIES

Choose the right
measurement technology.

Level, velocity and water quality measurements provide different information. Compare the options to find the right configuration for your application.

TIENet 310 Ex ultrasonic sensor with cable
310 Ex · ultrasonic level measurement
LaserFlow sensor for non-contact measurement
360 LaserFlow · area-velocity measurement
LevelRay with an optional pressure sensor for surcharged flow conditions
370 LevelRay · optional pressure sensing for surcharged flow
TIENet 301 interface and pH and temperature probe
301 · pH and temperature
01

TIENet 310 Ex

Non-contact ultrasonic level measurement

Installation and compatibility +

Measures level, not velocity. Hazardous-area use requires a TIENet barrier and installation that meets the applicable certification requirements.

Manufacturer documentation
02

TIENet 330

Bubbler level measurement

Installation and compatibility +

An internal module with a bubbler line and external desiccant cartridge. It determines liquid level from the air pressure needed to release bubbles from the line.

Manufacturer documentation
03

TIENet 350 Ex

Submerged area-velocity measurement: ultrasonic Doppler velocity and differential-pressure level sensing

Installation and compatibility +

Combines velocity measurement with differential-pressure level sensing. An external desiccant cartridge is required. Hazardous-area use depends on the barrier configuration and applicable certification.

Manufacturer documentation
04

TIENet 360 LaserFlow®

Non-contact area-velocity measurement: subsurface laser Doppler velocity and ultrasonic level sensing

Installation and compatibility +

Uses laser Doppler technology to measure velocity below the water surface and ultrasound to measure level. Check the firmware, mounting arrangement and channel geometry.

Manufacturer documentation
05

TIENet 360 LaserFlow® Ex

Non-contact area-velocity measurement for hazardous areas

Installation and compatibility +

Hazardous-area configuration with a certified barrier and mounting arrangement. Verify Ex certification requirements for the complete system.

Manufacturer documentation
06

TIENet 370 LevelRay

Non-contact FMCW radar level measurement

Installation and compatibility +

FMCW radar level sensor with a TIENet connection to Signature, confirmed by the manufacturer in 2026. Optional pressure sensing supports surcharged flow conditions. It does not measure velocity.

Manufacturer documentation
07

TIENet 301 + pH/temperature probe

pH and temperature

Installation and compatibility +

The probe connects through the TIENet 301 interface to add pH and temperature monitoring. Check compatibility before selecting an electrode; not all electrodes are supported.

Manufacturer documentation

These options are listed in current manufacturer documentation. Confirm firmware, wiring, power requirements and certifications. The base instrument does not include every probe or accessory.

Interfaces, expansion and integration +

TIENet 304

A control interface card with two assignable contact outputs. This is not a sensor.

TIENet 306

An interface for triggering ISCO automatic samplers and enabling proportional or event-based sampling. This is not a probe.

TIENet 307

A card with two 4–20 mA analog inputs for external instruments. Check power requirements, signal scaling, wiring and instrument compatibility.

TIENet 308

A card with two 4–20 mA analog outputs with configurable scaling. It sends signals to other equipment; it does not accept probe inputs.

TIENet 300

The meter’s internal board records internal variables and rainfall input. It is not a separately sold external probe.

TIENet expansion box

Adds connections to the TIENet bus without changing probe compatibility. Manufacturer documentation specifies a maximum of nine TIENet devices, including the 300 board, internal modules and cards. Check the current system architecture when configuring the meter.

TIENet barrier

An intrinsic safety barrier for compatible Ex configurations. It is a safety accessory, not a measurement device.

External instruments

Signature supports SDI-12, Modbus RS-485 ASCII/RTU and rainfall input. Use TIENet 307 for 4–20 mA inputs and TIENet 308 for outputs. Check each instrument’s protocol, register map and power requirements.

TIENet interfaces Expansion box documentation Signature manual
DuraTracker®: Multisensor flow meter and data logger
Manufacturer photo. Optional accessories may be shown.

02 / Multisensor flow meter and data logger

DuraTracker®

Monitor open-channel flow with ultrasonic, submerged Doppler area-velocity or non-contact LaserFlow technology. An IP68 enclosure, Bluetooth connectivity and data logging support field monitoring work.

Sewer networksSurface waterIndustrial pretreatmentWastewater treatment facilities
Key specifications +
  • IP68 enclosure
  • Operating temperature: −40 to 60 °C
  • 8 MB nonvolatile memory
  • Bluetooth, USB and Modbus ASCII/RTU
  • Optional LTE communication
Compatibility and configuration +
  • TIENet 310 Ex for ultrasonic level measurement; 350 Ex for submerged area-velocity measurement; 360/360 Ex for LaserFlow.
  • Supports up to four devices selected from 350 Ex, 310 Ex, 306 and 301, or one 360/360 Ex plus up to three devices from that list, according to the Rev. 3.0 data sheet.
  • TIENet 301 for pH/temperature monitoring; TIENet 306 for connecting a sampler.
  • The manufacturer’s TIENet page also lists the 305 rainfall/SDI-12 interface for DuraTracker. Confirm the configuration and firmware when requesting a quote.
  • DuraTracker and DuraTracker Ex are separate versions. Adding an Ex sensor does not make the standard logger a certified system for use in explosive atmospheres.
  • Battery life depends on the batteries, connected sensors and logging interval. Verify compatibility separately for newer devices such as LevelRay 370.

Reference: L-2304 Rev 3.0, 2025-04-16. Confirm configuration and local availability.

Ask about DuraTracker
6712: Portable automatic sampler
Manufacturer photo. Optional accessories may be shown.

03 / Portable automatic sampler

6712

A full-size automatic sampler for effluent, stormwater and discharge monitoring. It supports time-, flow- or event-based collection of sequential or composite samples. Ice in the insulated base keeps samples cool.

EffluentStormwaterCombined sewer overflowsDischarge monitoring and pretreatment
Key specifications +
  • 11 bottle configurations, including 24 × 1 L
  • Up to 21 L with optional Jumbo base
  • 12 VDC power supply
  • Maximum suction lift: 8.5 m
  • Programmable sample volume: 10–9,999 mL
  • Dry weight without battery: 15 kg
  • NEMA 4X, 6 / IP67 controller
Compatibility and configuration +
  • SDI-12 interface for compatible probes and devices.
  • Connects to Signature or DuraTracker through a TIENet 306 interface with a six-pin connector for event-triggered operation and flow-proportional sampling based on cumulative volume.
  • Optional 700 Series modules: confirm the model and availability when requesting a quote.
  • Samples are cooled with ice rather than active refrigeration. Select bottles, power supply, suction line and strainer to suit the sampling program.
  • Sampling for PFAS analysis requires suitable materials throughout the sampling setup. The instrument collects samples; it does not measure PFAS.

Reference: L-1107 Rev 3.0, 2026-01. Confirm configuration and local availability.

Ask about 6712
BLZZRD™: Portable refrigerated sampler
Manufacturer photo. Optional accessories may be shown.

04 / Portable refrigerated sampler

BLZZRD™

Automatic sampling with active refrigeration for short-term monitoring and remote sites. Built around the 6712 controller, it supports time-, flow- or event-based sampling using AC power or an external 12 V battery.

Stormwater runoffWatershed monitoringDischarge monitoringTemporary studies at remote sites
Key specifications +
  • Dry weight without battery: 34 kg
  • Dimensions: 71 × 47 × 80 cm
  • Maximum suction lift: 8.5 m
  • Programmable sample volume: 10–9,990 mL
  • Sequential sampling configurations: 14 × 950 mL, 4 × 1.8 L or 4 × 3.7 L
  • Composite sampling configurations: 9.5 or 19 L
  • IP67 controller; operating temperature: 0 to 49 °C
Compatibility and configuration +
  • SDI-12 interface for compatible devices.
  • Connects to Signature or DuraTracker through a TIENet 306 interface with a six-pin connector.
  • Optional transport kit and battery box.
  • The IP67 rating applies only to the controller. It does not mean the refrigerated sampler assembly can be submerged.
  • Bottles, suction line and strainer are specified separately. DC operation requires an external battery, with runtime dependent on the battery and operating conditions.

Reference: L-1156 Rev 2.1, 2024-05. Confirm configuration and local availability.

Ask about BLZZRD
BLZZRD installed in a service vehicle in a manufacturer case study from Chojnice, Poland
Manufacturer case study from Chojnice, Poland. The vehicle shown belongs to that installation, not Grupo Aberdeen.

PORTABLE REFRIGERATION · FIELDWORK

One sampling program.
Multiple monitoring sites.

BLZZRD can be moved between sites for short-term monitoring with active sample refrigeration. This manufacturer case study shows the sampler installed in a service vehicle.

  • Plan for transport. Allow for its 34 kg dry weight, overall dimensions, secure mounting and access at each site.
  • Power to suit the site. Use AC power or an external 12 V battery. Battery runtime depends on the configuration and operating conditions.
  • Sample collection and preservation. Choose bottles, a sampling schedule and preservation conditions that meet the requirements of the intended analysis.
View the manufacturer’s case study

02 / EXPLORE THE PRODUCT LINES

Your application.
The right equipment.

01

PORTABLE SAMPLING

Field sampling.

67126712CGLS
View application +

Portable automatic samplers to suit your sampling program and site conditions.

02

REFRIGERATION

Sample preservation.

58006712FRPortable BLZZRD
View application +

Stationary refrigerated samplers for monitoring stations, plus a portable refrigerated sampler for fieldwork.

03

FLOW AND LEVEL

A clearer view of flow.

SignatureDuraTracker / ExLaserFlow / ExLevelRayTIENet
View application +

Instruments and sensors for open-channel flow and non-contact level measurement, configured to suit your monitoring site.

04

ELECTROMAGNETIC FLOW MEASUREMENT

More ways to measure flow.

Teledyne Valeport Type 804Teledyne Valeport Model 801
View application +

Teledyne ISCO also features Teledyne Valeport instruments: Type 804 for full-pipe flow measurement and Model 801 for velocity measurement in open channels. Check suitability and availability for your application.

05

DATA MANAGEMENT

From logging to analysis.

FlowlinkFlowlink CipherCipher Go!FlowCalc
View application +

Software for accessing, organizing and analyzing monitoring data. Check compatibility and supported functions for each instrument.

Selection, availability and technical references +

Equipment selection and availability depend on your application. Confirm the specifications, configuration and local regulatory requirements before specifying an instrument.

Already using an ISCO instrument?

Tell us which model you use and how you use it so we can review your needs. Avalanche and Glacier are legacy models. The manufacturer identifies BLZZRD as the current alternative.

Ask about legacy equipment

Manufacturer documents may be available in English.

THE NEXT STEP

Let’s talk about
your project.

Tell us your business activity, location and what you need to resolve. For an existing system, include the model and the issue you have noticed. For a new system, share its intended use and any known flow rate or capacity.

Contact Grupo Aberdeen
WhatsApp