BLZZRD · monitoring in Chojnice, Poland. Manufacturer source This is not a Grupo Aberdeen project.
MEASURE · RECORD · SAMPLE
From sensor to sample.
Choose the flow meter, sensors and sampler as a system, matched to the conditions at your monitoring site.
01 / CONFIGURABLE PLATFORM
Signature. The right technology for your discharge monitoring.
A configurable flow monitoring platform for open channels and discharge points. It supports level and area-velocity measurement, logs multiple parameters and keeps an event history to help assess data integrity.
Choose ultrasonic or bubbler level measurement, submerged area-velocity sensing, LaserFlow or LevelRay radar. Add pH and temperature monitoring as your application requires.
Sensors and modules are specified separately to suit the channel, water quality, installation conditions and safety requirements.
Product image from the manufacturer. Sensors and interfaces vary with the configuration.
MEASUREMENT TECHNOLOGIES
Choose the right measurement technology.
Level, velocity and water quality measurements provide different information. Compare the options to find the right configuration for your application.
310 Ex · ultrasonic level measurement360 LaserFlow · area-velocity measurement370 LevelRay · optional pressure sensing for surcharged flow301 · pH and temperature
01
TIENet 310 Ex
Non-contact ultrasonic level measurement
Installation and compatibility +
Measures level, not velocity. Hazardous-area use requires a TIENet barrier and installation that meets the applicable certification requirements.
An internal module with a bubbler line and external desiccant cartridge. It determines liquid level from the air pressure needed to release bubbles from the line.
Submerged area-velocity measurement: ultrasonic Doppler velocity and differential-pressure level sensing
Installation and compatibility +
Combines velocity measurement with differential-pressure level sensing. An external desiccant cartridge is required. Hazardous-area use depends on the barrier configuration and applicable certification.
Uses laser Doppler technology to measure velocity below the water surface and ultrasound to measure level. Check the firmware, mounting arrangement and channel geometry.
FMCW radar level sensor with a TIENet connection to Signature, confirmed by the manufacturer in 2026. Optional pressure sensing supports surcharged flow conditions. It does not measure velocity.
The probe connects through the TIENet 301 interface to add pH and temperature monitoring. Check compatibility before selecting an electrode; not all electrodes are supported.
These options are listed in current manufacturer documentation. Confirm firmware, wiring, power requirements and certifications. The base instrument does not include every probe or accessory.
Interfaces, expansion and integration +
TIENet 304
A control interface card with two assignable contact outputs. This is not a sensor.
TIENet 306
An interface for triggering ISCO automatic samplers and enabling proportional or event-based sampling. This is not a probe.
TIENet 307
A card with two 4–20 mA analog inputs for external instruments. Check power requirements, signal scaling, wiring and instrument compatibility.
TIENet 308
A card with two 4–20 mA analog outputs with configurable scaling. It sends signals to other equipment; it does not accept probe inputs.
TIENet 300
The meter’s internal board records internal variables and rainfall input. It is not a separately sold external probe.
TIENet expansion box
Adds connections to the TIENet bus without changing probe compatibility. Manufacturer documentation specifies a maximum of nine TIENet devices, including the 300 board, internal modules and cards. Check the current system architecture when configuring the meter.
TIENet barrier
An intrinsic safety barrier for compatible Ex configurations. It is a safety accessory, not a measurement device.
External instruments
Signature supports SDI-12, Modbus RS-485 ASCII/RTU and rainfall input. Use TIENet 307 for 4–20 mA inputs and TIENet 308 for outputs. Check each instrument’s protocol, register map and power requirements.
Manufacturer photo. Optional accessories may be shown.
02 / Multisensor flow meter and data logger
DuraTracker®
Monitor open-channel flow with ultrasonic, submerged Doppler area-velocity or non-contact LaserFlow technology. An IP68 enclosure, Bluetooth connectivity and data logging support field monitoring work.
TIENet 310 Ex for ultrasonic level measurement; 350 Ex for submerged area-velocity measurement; 360/360 Ex for LaserFlow.
Supports up to four devices selected from 350 Ex, 310 Ex, 306 and 301, or one 360/360 Ex plus up to three devices from that list, according to the Rev. 3.0 data sheet.
TIENet 301 for pH/temperature monitoring; TIENet 306 for connecting a sampler.
The manufacturer’s TIENet page also lists the 305 rainfall/SDI-12 interface for DuraTracker. Confirm the configuration and firmware when requesting a quote.
DuraTracker and DuraTracker Ex are separate versions. Adding an Ex sensor does not make the standard logger a certified system for use in explosive atmospheres.
Battery life depends on the batteries, connected sensors and logging interval. Verify compatibility separately for newer devices such as LevelRay 370.
Manufacturer photo. Optional accessories may be shown.
03 / Portable automatic sampler
6712
A full-size automatic sampler for effluent, stormwater and discharge monitoring. It supports time-, flow- or event-based collection of sequential or composite samples. Ice in the insulated base keeps samples cool.
EffluentStormwaterCombined sewer overflowsDischarge monitoring and pretreatment
Key specifications +
11 bottle configurations, including 24 × 1 L
Up to 21 L with optional Jumbo base
12 VDC power supply
Maximum suction lift: 8.5 m
Programmable sample volume: 10–9,999 mL
Dry weight without battery: 15 kg
NEMA 4X, 6 / IP67 controller
Compatibility and configuration +
SDI-12 interface for compatible probes and devices.
Connects to Signature or DuraTracker through a TIENet 306 interface with a six-pin connector for event-triggered operation and flow-proportional sampling based on cumulative volume.
Optional 700 Series modules: confirm the model and availability when requesting a quote.
Samples are cooled with ice rather than active refrigeration. Select bottles, power supply, suction line and strainer to suit the sampling program.
Sampling for PFAS analysis requires suitable materials throughout the sampling setup. The instrument collects samples; it does not measure PFAS.
Manufacturer photo. Optional accessories may be shown.
04 / Portable refrigerated sampler
BLZZRD™
Automatic sampling with active refrigeration for short-term monitoring and remote sites. Built around the 6712 controller, it supports time-, flow- or event-based sampling using AC power or an external 12 V battery.
Stormwater runoffWatershed monitoringDischarge monitoringTemporary studies at remote sites
Key specifications +
Dry weight without battery: 34 kg
Dimensions: 71 × 47 × 80 cm
Maximum suction lift: 8.5 m
Programmable sample volume: 10–9,990 mL
Sequential sampling configurations: 14 × 950 mL, 4 × 1.8 L or 4 × 3.7 L
Composite sampling configurations: 9.5 or 19 L
IP67 controller; operating temperature: 0 to 49 °C
Compatibility and configuration +
SDI-12 interface for compatible devices.
Connects to Signature or DuraTracker through a TIENet 306 interface with a six-pin connector.
Optional transport kit and battery box.
The IP67 rating applies only to the controller. It does not mean the refrigerated sampler assembly can be submerged.
Bottles, suction line and strainer are specified separately. DC operation requires an external battery, with runtime dependent on the battery and operating conditions.
Manufacturer case study from Chojnice, Poland. The vehicle shown belongs to that installation, not Grupo Aberdeen.
PORTABLE REFRIGERATION · FIELDWORK
One sampling program. Multiple monitoring sites.
BLZZRD can be moved between sites for short-term monitoring with active sample refrigeration. This manufacturer case study shows the sampler installed in a service vehicle.
Plan for transport. Allow for its 34 kg dry weight, overall dimensions, secure mounting and access at each site.
Power to suit the site. Use AC power or an external 12 V battery. Battery runtime depends on the configuration and operating conditions.
Sample collection and preservation. Choose bottles, a sampling schedule and preservation conditions that meet the requirements of the intended analysis.
Instruments and sensors for open-channel flow and non-contact level measurement, configured to suit your monitoring site.
04
ELECTROMAGNETIC FLOW MEASUREMENT
More ways to measure flow.
Teledyne Valeport Type 804Teledyne Valeport Model 801
View application +
Teledyne ISCO also features Teledyne Valeport instruments: Type 804 for full-pipe flow measurement and Model 801 for velocity measurement in open channels. Check suitability and availability for your application.
05
DATA MANAGEMENT
From logging to analysis.
FlowlinkFlowlink CipherCipher Go!FlowCalc
View application +
Software for accessing, organizing and analyzing monitoring data. Check compatibility and supported functions for each instrument.
Selection, availability and technical references +
Equipment selection and availability depend on your application. Confirm the specifications, configuration and local regulatory requirements before specifying an instrument.
Already using an ISCO instrument?
Tell us which model you use and how you use it so we can review your needs. Avalanche and Glacier are legacy models. The manufacturer identifies BLZZRD as the current alternative.
Manufacturer documents may be available in English.
THE NEXT STEP
Let’s talk about your project.
Tell us your business activity, location and what you need to resolve. For an existing system, include the model and the issue you have noticed. For a new system, share its intended use and any known flow rate or capacity.